The GV80 vacuum pump is capable of continuous operation with the ability to handle large volumes of condensable vapours.
The GV110 vacuum pump includes all the features of the GV80 and offers additional features including an integrated variable speed drive, modern acoustic enclosure and improved pumping performance.
The GV80 is available as a stand-alone unit or can be combined with an EH500 hydrokinetic drive mechanical booster for increased pumping speed.
The GV80 vacuum pump is capable of continuous operation with the ability to handle large volumes of condensable vapours. With clean, quiet pumping and minimal service disruption, the GV80 provides consistent output and repeatable pumping performance.
The GV110 vacuum pump includes all the features of the GV80 and offers additional features including an integrated variable speed drive, modern acoustic enclosure and improved pumping performance.
It’s easy for you to get started with a range of packages and pumping systems designed for a wide range of applications and environments. The GV80 is available as a stand-alone unit or can be combined with an EH500 hydrokinetic drive mechanical booster for increased pumping speed.
Unit | GV100 | GV80 | Drystar® GV80/EH500 | ||
---|---|---|---|---|---|
Peak pumping speed 50 Hz | m³/hr (cfm) | 110 (64.7) | 80 (47) | 390 (230) | |
Peak pumping speed 60 Hz | m³/hr (cfm) | – | 94 (56) | 471 (277) | |
Ultimate pressure | mbar (Torr) | 6 x 10-3 (4.5 x 10-3) | <3 x 10-2 (<2 x 10-2) | <3 x 10-2 (<2 x 10-2) | |
Full load power | @ ultimate pressure | Kw (hp) | 2.6 kW (3.5) | 3.6 (4.8) | 4.3 (5.6) |
@ peak pumping load | Kw (hp) | 4.5 kW (4.7) | 5.8 (7.8) | 6.7 (9.0) | |
Electrical | Supply options | EU-US-CN 50/60Hz, 400V/50Hz – 460V/60Hz – 380V/50Hz ASIA 50/60 Hz 200V/50Hz, 200V/60Hz, 380V/60Hz Note: See part number for specific voltage offerings. | |||
Vacuum couplings | Inlet | ISO40 | ISO40 | ISO100 | |
Exhaust | NW40 | ||||
Cooling | Water | Water | Water/Air | ||
Cooling water | Flow | l/min (gal/min) | 5 (1.32) | 8 (2.1) | |
Supply pressure (MAX) | bar.a (psig) | 8 (116) | |||
DP across pump (MIN) | bar.a (psig) | 2.1 (30) | |||
Temperature | °C (°F) | 5 – 35 (41-95) | |||
Connection | In | 1/2″ Quick connect coupling (mating half provided) | |||
Out | 1/2″ Quick connect plug (mating half provided) | ||||
Purge gas (N2 or CDA) | Pressure | bar.a (psig) | 0.5 (6-8) | ||
Light duty | sl/min | 15 (typically) | |||
Connection | 1/4″ Quick connect coupling (mating half provided) | ||||
Dimensions | L x W x H | mm (in) | 1060 x 502 x 316 (42 x 20 x 12.5) | 860 x 607 x 344 (33.8 x 23.9 x 13.5) | 932 x 607 x 624 (36.7 x 23.9 x 24.6) |
Footprint | m2 (ft2) | 0.532 (5.73) | 0.43 (4.63) | ||
Weight | Kg (lbs) | 210 kg (463) | 165 (364) | 240 (529) | |
Noise level with exhaust silencer | dB(A) | <75 | <78 | ||
Exhaust Back Pressure (MAX) | bar.a (psig) | 1.3 (0.4) | |||
Lubrication | Volume | l (gal) | 0.4 (0.1) | 0.4 (0.1) | 1.4 (0.4) |
Type | Hydrocarbon | SHC 629 | SHC 629 | SHC 629/Ultragrade 20 | |
PFPE | – | YVAC 25/6 | YVAC 25/6 / YVAC 16/6 | ||
Pump Electrical motor rating | kW/HP | 4/4.5 | 4/4.5 | – | |
Typical pump rotation speed – 50Hz electrical supply | rev.min-1 | 4100 | 3000 | – | |
Typical pump rotation speed – 60Hz electrical supply | rev.min-1 | 4100 | 3600 | – | |
Protection grade | IP | 42 | 55 | – | |
Warm-up time to pump operating temperature | min | 15 | 15 | – | |
Ambient operating temperature range | °C (°F) | 0 to 40 (32 to 104) | 0 to 40 (32 to 104) | – | |
Maximum ambient operating humidity | RH | 80% | 100% | – |