MaxCool Cryochillers

MaxCool Cryochillers

Improve vacuum

Edwards Polycold® MaxCool Cryochillers are closed loop cryogenic refrigeration systems that effectively capture water vapour, which comprises 65% to 95% of the residual gas in high vacuum systems. MaxCool Cryochillers are the most cost-effective upgrade that you can add to any diffusion-pumped, turbopumped, or helium-cryopumped system.

Achieve lower vacuum levels quickly

These cryochillers can be used to capture water vapour and other condensable substances by freezing them onto a cold surface such as a cryocoil or chevron baffle. MaxCool Cryochillers are also used to cool and heat objects such as electrostatic chucks used in semiconductor wafer processing. The different models in our range provide 2,000, 2,500 or 4,000 watts of cooling.

Water Vapour Pumping

Water vapour is typically the most reactive contaminant present in high vacuum systems. With our MaxCool Cryochillers you can expect an increase in product throughput in your existing system of 20% to 100% and improve quality of deposition.

The MaxCool Advantage

Compliant with European Application Refrigerants (EC 1005/2009)

When added to your vacuum system, MaxCool Cryochillers can dramatically reduce pumpdown times and increase product throughput. The MaxCool will pump water vapour within minutes from start and can defrost in less than four minutes, giving true fast-cycle capability. It also has an option called Rapid Cool to Cool, which eliminates the waiting period after defrost, enabling your system to perform more production cycles per shift. Using patented Polycold® refrigerant mixtures, our MaxCool Cryochillers work on the principle of Meissner trapping. Water vapour is captured by condensation on a cryogenically cooled surface, called a Meissner coil. The Meissner (cryocoil) is mounted directly in the vacuum chamber so conductance is not limited by ports, manifolds, valves and baffles. The cryocoil is easy to install and can be adapted to fit any system. It does not need a high vacuum valve.

Benefits

  • Increased productivity with rapid cool to cool option
  • Option for power management to minimize cost of ownership
  • Temperature control
  • Patented Green refrigerant charge is globally compliant, non-toxic and non-flammable
  • Based on Polycold®’s proven, innovative, dependable mixed gas refrigeration
  • Compliant to EU PED and MD
  • TUV Rheinland Listed to NRTL/CANADA Safety Standards
  • ISO 9001:2008 certified manufacturer

MaxCool models specifications

MaxCool 2000MaxCool 2500LMaxCool 4000H
Maximum Cooling Capacity2,000 W2,500 W4,000 W
Temperature at Maximum Cooling Capacity-111 °C-120 °C-98 °C
Coldest Temperature-142 °C-145 °C-133 °C
Ultimate Operating Pressure (25% of max pumping speed)3E-9 torr8E-10 torr5E-8 torr
Typical Cold Trap Area1.1 m21.4 m22.2 m2
Maximum Water Vapor Pumping Speed from Typical Cold Trap Area163,900 l/s208,600 l/s327,800 l/s
Conservative Maximum Cold Trap Area*1.5 m22.0 m22.8 m2
Electrical Consumption (Standby Mode)5.5 kW11.4 kW12.0 kW
Electrical Consumption (Cool Mode, Typical Load)6.2 kW13.9 kW12.4 kW
Electrical Consumption (Cool Mode, Max Load)8.8 kW19.2 kW19.2 kW
Cooling water flow for 13 °C6.8 l/min15.1 l/min15.1 l/min
Cooling water flow for 18 °C9.1 l/min18.2 l/min18.2 l/min
Cooling water flow for 24 °C13.6 l/min27.3 l/min27.3 l/min
Cooling water flow for 29 °C27.6 l/min54.1 l/min54.1 l/min
European PED-CompliantYesYesYes
Nontoxic RefrigerantsYesYesYes
Non-flammable RefrigerantsYesYesYes